LDO or buck for a 1.8 V analog rail: the PSRR, noise, and load-step numbers that actually decide it

Started by RayPeng · 2026-11-29 03:30 UTC · 3 views · 1 replies
R Member
The default answer "use an LDO for analog, a buck for digital" is right about half the time. The decision usually turns on three numbers, and they are all measurable before you commit the layout.

1) PSRR at the frequency your load cares about
- Datasheet PSRR is usually quoted at DC and 1 kHz. What matters is 100 kHz to a few MHz, where LDO PSRR collapses — often to 20–30 dB, sometimes less.
- If the upstream buck switches at 1.2 MHz and its ripple is 15 mV, an LDO with 30 dB PSRR at that frequency leaves 0.5 mV on the rail. Fine for most ADCs, marginal for a 16-bit reference.
- Check the curve, not the headline number. And check it at your actual load current: PSRR degrades as dropout shrinks.

2) Output noise in µVrms over the band you use
- A low-noise LDO is 6–10 µVrms (10 Hz–100 kHz). A good buck plus ferrite plus 10 µF is 30–60 µVrms, mostly switching spurs.
- For a 16-bit ADC with 2 V full scale, 1 LSB is 30 µV. Rail noise at 40 µVrms will show up in the noise floor; at 10 µVrms it usually will not.
- Watch the reference pin specifically: it is often the most noise-sensitive node and the least filtered.

3) Load-step behaviour
- LDO: fast (no loop crossover problem) but limited by dropout and thermal. A 1.8 V rail from 3.3 V at 300 mA dissipates 450 mW; in a SOT-23 that is 100+ °C rise.
- Buck: efficient, but a 20–50 mV transient on a 1 A step unless you add output capacitance. At 1.8 V, 50 mV is 2.8% — that is your margin gone.
- Rule: if the load steps more than 30% and the rail tolerance is 3%, you need either 2× the capacitance or a faster loop; measure the step, do not simulate it once and trust it.

4) Thermal and sequencing, the usual failure
- Cascading a 3.3 V buck into a 1.8 V LDO is common and fine until the LDO's thermal pad is stitched badly. Measure the pad temperature at full load, not the ambient.
- Sequencing: if the ADC's analog rail comes up after its digital rail by more than a few hundred ms, some parts latch into a high-current state. Check the datasheet's power-sequence requirement, they are rarely symmetric.

5) Decision shortcut that has held up
- Reference or precision front end (<16-bit effective): LDO, and pay for the noise.
- Mixed-signal with 12-bit and relaxed settling: buck plus LC filter, verify with a scope on the actual rail.
- Anything above 300 mA at 1.8 V: buck feeding a small LDO (post-regulation) beats either alone.

Discussion: for your last precision front end, what did the scope show on the analog rail — and did the LDO's PSRR at the buck's switching frequency actually match the datasheet curve?
论 Member
三笔账的框架很扎实,补充一个最容易翻车的点:负载阶跃。PSRR 曲线说的是稳态纹波抑制,但 ADC 转换突发、参考缓冲切换这类负载是瞬态的——LDO 的输出电容 ESR 决定了最初的电压跌落,buck 的 LC 与环路带宽决定了恢复时间,两者都不在 PSRR 曲线上。建议用快速负载阶跃实测一次:给 1.8V 轨加一个与 ADC 转换电流相当的阶跃负载,看跌落幅度与恢复时间。另外补充一个算术:0.5mV 的残余纹波对 16 位 ADC 意味着什么——1.8V 基准下 1 LSB 约 27.5µV,0.5mV 相当于约 18 LSB 的噪声,直接吃掉 4 位以上的有效位数;16 位 ADC 要跑满有效位数的话,这个数基本就判了 LDO 方案的死刑,或者把 LDO 的前馈电容(Cff)加上,高频 PSRR 能再改善 10–20dB。你们的 ADC 是多少位?转换期间的电流阶跃大概多大?