High-side current sensing at 400 V - isolation approaches?

Started by ADTRAN_Tech_Young · 2026-11-24 03:52 UTC · 15 views · 2 replies
A Member
Sensing current on a 400 V rail needs isolation that doesn't kill accuracy. What approach are you using - isolated amplifiers, Hall, or something else?
E Member
Depends on the accuracy you need at 400 V, but our choice came down to shunt + isolated amplifier, and the deciding numbers were not the datasheet gain error.

What we measured on a 1 mΩ shunt with an isolated front end: 0.4% total at 25 °C, gain drift 80 ppm/K over 0–70 °C, and 200 ns propagation delay. At 20 kHz switching that delay is 1.4° of phase, which matters if you close a current loop — we compensate the phase, not the gain.

Two things that bit us:

1) Common-mode dv/dt, not CMTI margin. At 400 V with 50 V/ns edges you are well inside the amplifier rating, but the isolated supply coupling still injects 30–60 mV into the sense path; a 100 pF imbalance in the input filter is enough. We fixed it with a symmetric RC (100 Ω + 100 pF per leg) and a guard trace tied to the isolated ground.

2) Creepage is a mechanical problem, not a layout one. 8 mm over a 2 mm slot looks fine until conformal coating bridges it. We now put the coating keep-out on the assembly drawing.

Hall was simpler to isolate but 1% offset drift over temperature was not acceptable where we need 0.5% at the trip point. For protection-level accuracy Hall is fine; for metering or closed-loop control, shunt + isolation.

What switching frequency are you running, and is the current needed for control or only for protection?
X Member
结论:400 V 母线采样不要先按隔离放大器、霍尔、光耦这些器件方式分类,而应先按应用需求分层。如果用于闭环电流环,且带宽只有几 kHz 到几十 kHz、精度目标在 1% 以内,通常选用分流器加隔离放大器或隔离 Σ-Δ 调制器,原因是增益与失调可以在 DSP 里标定,且线性度较好;如果只做过流保护或慢速监测,用隔离运放加比较器更省,不必为精度付出成本;如果是几百 A 的大电流,且能接受 1% 量级的精度,闭环霍尔或磁通门更合适,因为分流器的功耗、铜排温升和 DCR 热漂移会变成主要误差源。选用分流器方案时,应把分流器材料与阻值温漂、Kelvin 走线、隔离器输入偏置电流、隔离侧供电纹波一起作为误差项考虑,不能只关注数据手册的增益误差。

限制主要在三处。第一,共模 dv/dt 与 CMTI:400 V 桥臂的共模跳变会通过隔离器输入端的寄生电容注入,表现为输出尖峰;选型时要确认数据手册给出的是共模瞬态条件下的指标,而不能只看静态 CMRR。第二,传播延时与相位:隔离放大器的延时通常在百 ns 到 µs 量级,隔离 Σ-Δ 调制器还要叠加数字滤波器的群延时,在电流环里必须按实际延时补偿相位,不能只按采样周期计算。第三,隔离电源:隔离侧偏置的纹波和耦合会直接串到输出,摆率不够时还会在共模跳变期间出现输出塌陷。验证时建议用差分探头同时观察分流器两端与隔离器输出,做静态零点对温度的扫描,再用阶跃或共模脉冲测延时与恢复时间;DSP 侧则应把采样触发点、数字滤波群延时和 PWM 更新时刻对齐,否则测出来的“精度”会被相位误差掩盖。以上是选型分层思路,具体数值需按所选器件的数据手册与你实际的分流器、布局核对后判断。