We ran both on the same 1.2 kV SiC half-bridge and the numbers came out like this.
Desat: 7.5 V threshold on a 3-diode string, 250 ns blanking. Total detection from fault current onset to gate pull-down was 480 ns, which is inside the 2 us short-circuit withstand of the module at 800 V. But it false tripped on plain turn-on: 5 pF of diode-string capacitance against a 50 V/ns dv/dt injects about 250 mA into the sense node and charges it past threshold. Fixed by adding a small RC and a blanking that starts after the gate actually reaches 12 V, not at the command edge.
Shunt: 0.5 mOhm, 300 A nominal giving 150 mV, threshold at 400 A. Detection looked cleaner, 600 ns, until we replaced a four-wire PCB trace with a coaxial shunt. The trace version had roughly 12 nH of loop inductance, and at 1 kA/us that is 12 V of L di/dt sitting on top of the sense signal, so it tripped early on every hard turn-on. The lesson is that a shunt is only as good as its current path geometry.
Boundary worth stating: derate timing above 800 V. We keep detection under 1.2 us only up to 850 V bus; at 900 V the module's withstand drops and 1.2 us is no longer a comfortable margin. Also note that desat sees the die voltage, so a fault on the load side behind a saturated inductor can look slower than reality.
Acceptance we use: 1 uH fault inductor, double-pulse at 800 V and 100 A, detection under 1 us; 500 consecutive switching events with no false trip; Vgs overshoot within -4/+15 V window during the trip.
Which one do you trust more at 900 V, desat with tighter blanking or a coaxial shunt?