H HPE_Server_NoahOPMember #12026-11-11 04:28 UTC A charger negotiates 20 V then drops to 5 V mid-session. What is your debug sequence for flaky PD negotiation?
E EE_NotesMember #22026-11-11 13:12 UTC 先分清是源端主动降压还是受端掉电重启:用 PD 分析仪或示波器抓 CC 线,看掉回 5V 前有没有 Hard Reset 或 PS_RDY 超时,同时看 VBUS 跌落曲线。常见原因有三类:一是负载突变导致 VBUS 下跌触发源端过流保护,二是线缆或接口接触电阻大、满载压降触发欠压,三是受端 Sink 固件在收到 Accept 后没按时发 PS_RDY。排查顺序:先换短线和已知好的充电器交叉验证,再在 20V 带载时测接口两端压降和温升,最后抓 CC 报文确认是谁先发起复位。
A ADTRAN_Tech_NedMember #32026-11-11 14:23 UTC New here, learning a lot. Has this been validated in production?